Measurement ranges
using 8956 ANALOG UNIT /option 5 mV to 20 V/division, 12 ranges (20 division f.s.), resolution: 1/100 of range
Frequency band DC to 10 MHz ±3 dB (using 8956 ANALOG UNIT /option)
8961 High Voltage 2 Channel Input Module
Time axisat memory function 5 µs to 5 minutes/division, 26 settings; external sampling (100 samples/division, desired setting)
Measurement function Memory, Recorder,
Recorder & Memory (Version 2.00 or later),
FFT (Version 2.00 or later)
Number of input channels 8860 : Analog (up to 8 channels) + logic (16 channels standard) or Scanner Input (up to 64 channels)
8861 : Analog (up to 16 channels) + logic (16 channels standard) or Scanner Input (up to 128 channels)
Memory capacity
(MEMORY BOARDS sold separately) 8860 : 32 M words with 9715×1, up to 1GW with 9715-03×1
8861 : 64 M words with 9715×2, up to 2 GW with 9715-03×2
60GB Hard disk drive (optional), Floppy disk drive (optional USB), Two Type II PC card slot upto 1GB each.
Interfaces USB1.1, LAN, GP-IB (via PC card slot, GP-IB card optional)
Recording and display 10.4-inch TFT color LCD, 216 mm × 30 m , thermal paper roll
Other functions Scaling, Vernier function, Cursor measurement,
Comment insertion, multiple triggering, dual sampling
Power supply 100 to 240 V AC (50/60 Hz)
Dimensions, mass 8860 : 330 mmW × 250 mmH × 184.5 mmD, 8.0 kg
8861 : 330 mmW × 250 mmH × 284.5 mmD, 10.5 kg
Accessories Power cord (1), input cord label (1), WaveViewer software (1)
|